ChipReadResult

The outcome of ChipReader.read.

  • Complete: every step ran. Some requested files may still be missing or unreadable; they are listed in ChipRead.fileErrors.

  • Partial: access was granted, then the read stopped part way, for example because the document left the reader's field or the session ended after a chip-authentication key switch. What was read before is kept, and the checks are run over it.

  • Failed: access was not granted (for example the access key does not match), or the chip is blank (io.lightine.tessera.types.errors.ChipBlank). Nothing was read from the eMRTD application.

None of them is a judgment on the document: a chip that cannot be read, or that is blank, does not by itself make a document unusable (ICAO Doc 9303 Part 11, section 2).

In Swift these are the classes ChipReadResultComplete, ChipReadResultPartial and ChipReadResultFailed; none is generic.

May gain members in a later release: an exhaustive when over it then stops compiling until the new member is handled. An else branch keeps it compiling without handling the new member: that is your choice, and today the compiler warns that such an else is redundant.

Experimental: see ExperimentalTesseraChipApi.

Since

1.0.0

Inheritors

Types

Link copied to clipboard

Every step ran; read holds what the chip gave.

Link copied to clipboard

Access was not granted, or the chip is blank, because of error. access says how far access got: null when no access protocol completed.

Link copied to clipboard

The read stopped because of stoppedBy; read holds what was read before.